LED Layouts by Tent Size (2×2, 2×4, 3×3, 4×4)
Builder’s guide to LED tent layouts: recommended watts, bar/panel placement, hanging heights, and how to measure PPFD for uniform results.
Use this step-by-step to size watts, place bars and panels, and tune for even in popular tent sizes.
Step 1 Pick your PPFD target
- Seedlings / clones: 150–300 µmol/m²/s
- Leafy herbs & greens: 300–500 µmol/m²/s
- Fruiting / flowering crops: 600–900 µmol/m²/s
Aim for ≥ 0.8 (min ÷ max) across the canopy.
Step 2 Choose a modern watt range
Rule of thumb with efficient fixtures (≥2.7 µmol/J):
| Tent | Typical watts | Notes |
|---|---|---|
| 2×2 | 100–150 W | Compact panel or 2 mini bars |
| 2×4 | 200–320 W | Two long bars or a 4-bar unit |
| 3×3 | 250–400 W | 6–8 bars or panel plus sidebars |
| 4×4 | 400–650 W | 8–10 bars or two 240–320 W panels |
Step 3 Place the fixtures
Keep 6–8″ from tent walls and drivers for airflow. Start with the heights below, then fine-tune.
2×2 layout
Height: 10–14″. Center a compact panel or run two mini bars in parallel.
2×4 layout
Height: 12–16″. Two long bars lengthwise, or a 4-bar frame evenly spaced.
3×3 layout
Height: 12–18″. Six–eight bars in a grid, or one panel plus sidebars to lift edges.
4×4 layout
Height: 14–20″. Eight–ten bars, or two mid-size panels with a slight overlap zone.
Drivers & cable management
Step 4 Measure & tweak
- Hot center: raise 2–4″ or dim 10–20%.
- Dark corners: drop 1–2″, add sidebars, or widen spacing.
- Too low overall: lower height or increase output.
Re-measure at the and repeat until the map evens out.
How to re-measure at the canopy
- Use a for true readings. Phone are OK for relative checks only.
- Set the probe at canopy height (top leaves). Turn fans down briefly to steady the reading.
- Measure a 9-point grid: center, mid-edges, and corners. Note min, max, and average.
- Calculate uniformity: min ÷ max. Target ≥ 0.8.
- Adjust: raise / lower 1–2″, dim 5–10%, or nudge bar spacing; then re-measure the same 9 points.
Tip: If you must convert lux → PPFD for white LEDs, treat it as an estimate only—each spectrum is different.
FAQs
What’s the best way to space LED bars?
Quick answer: split the area into equal lanes; keep 6–8″ from walls and 4–6″ between bars.
- 2×4: two long bars lengthwise or four bars evenly spaced.
- 3×3: 6–8 bars in a grid; leave a small center gap to reduce hotspots.
- 4×4: 8–10 bars; balance overlap zones to lift edges.
Can I mix different fixtures or wattages?
Yes— just match spectrum and dim to blend. Place the higher-output unit slightly higher or off-center.
- Panel + sidebars: dim the panel 10–20% to lift edges evenly.
- Two panels: offset the seam by 2–3″ to reduce a hot stripe.
- Always re-check a 9-point PPFD map after any change.
What height should I start at for each tent?
Starting points: 2×2: 10–14″, 2×4: 12–16″, 3×3: 12–18″, 4×4: 14–20″.
Lower for veg targets; raise for higher watts or to widen coverage. Adjust by 1–2″ and re-measure.
PPFD
Usable light at the canopy in µmol/m²/s.
Uniformity
How even the light is: lowest PPFD divided by highest. A result ≥ 0.8 is considered good.
Canopy
The top leaf layer of your plants. This is the reference height for all PPFD measurements.
PAR meter
A handheld sensor that measures photosynthetic light (PPFD) directly. Best tool for dialing in LEDs.
Lux app
A phone light meter. Useful for before/after comparisons, but lux → PPFD conversions are only rough estimates.
Not sure if your layout is really even?
Share your tent size, fixture model, and a quick PPFD or lux map. We’ll suggest bar spacing, height, and dimmer settings so you hit your targets without guesswork.
Further reading
Connect this layout guide with the broader lighting and equipment choices for your system:
